Catalogue case reference · page 25

500 T/day landfill leachate treatment reference.

The supplied JINFAN WATER catalogue records the following capacity, raw-water indicators, reported treated-water indicators and process route. These figures describe one reference case—not a performance guarantee for a different site.

Reference sourceJINFAN WATER catalogueSource: supplied English catalogue, page 25
Landfill leachate treatment case imagery from JINFAN catalogue

Reported reference data

The exact boundary reproduced from the source.

Processing capacity500 T/day
Raw COD>9,000 mg/L
Raw conductivity>30,000 µS/cm
Reported treated COD≤100 mg/L
Reported treated conductivity≤800 µS/cm
Interpretation rule: the source reports these values for the reference case. Actual design and performance depend on representative wastewater analysis, loading variation, pretreatment, temperature, operating control, membrane design and the agreed discharge or reuse boundary.

Reported process route

Four treatment stages are listed.

01

Air flotation

Initial removal of floatable and suspended contaminants where applicable.

02

Biochemical treatment

Biological conversion and sludge management against the actual wastewater profile.

03

MBR

Membrane bioreactor separation to stabilise suspended-solids control before advanced treatment.

04

Reverse osmosis

Membrane polishing and dissolved-solids reduction, with concentrate requiring a defined pathway.

What must be revalidated

A new project cannot inherit these numbers automatically.

  • Representative influent analysis and variability
  • Ammonia, salts, refractory organics and toxicity
  • Existing biological-system condition
  • Required discharge or reuse standard
  • RO recovery, fouling risk and concentrate pathway
  • Utilities, footprint, climate and operation capability
Evidence ledger

Publication boundary

Source
JINFAN WATER English catalogue
Source page
25
Client identity
Not published in the supplied case page
Use on website
Technical reference only; no universal guarantee

Need a project-specific treatment route?

Send actual flow, test data, current process, target standard and concentrate-disposal conditions.

Start technical review →